Fluke TruTest · Stored results · PDF reports
Electrical safety testing with proper reports
Every reading captured, stored and turned into a clear report with Fluke TruTest software. Proof, not a tick on a clipboard.
- 5.0 from 120 reviews
- NSW Lic 260121C
- Local since 2014

Anyone can write "tested OK" on an invoice. We would rather show you the numbers. Every safety test we carry out is measured with calibrated instruments, captured digitally at the board, and stored against your property in Fluke TruTest data management and reporting software.
You receive a professional report that lists each circuit, what was tested, what it measured and whether it passed. Because the data is stored, the next inspection can be compared against the last one, so a circuit that is slowly getting worse is caught before it fails.
- Earth continuity
- 0.21 Ω
- PASS
- Insulation resistance
- >200 MΩ
- PASS
- Fault loop impedance
- 0.42 Ω
- PASS
- Safety switch trip
- 18 ms
- PASS
- Polarity
- Correct
- PASS
When a safety report is worth having
- Buying or selling a property and you want to know what is behind the walls
- Landlords and property managers who need a record of electrical condition
- Businesses, strata and facilities with insurance or compliance obligations
- After a renovation, storm, flood or fire damage
- Older homes that have never had the wiring checked
- Sign-off and handover documentation on new work
What we test and record
Earth continuity
Confirms the protective earth is intact back to the board on every circuit.
Insulation resistance
Finds cable insulation that is breaking down before it becomes a fault or a fire risk.
Polarity and connections
Checks active, neutral and earth are where they should be at every point.
Earth fault loop impedance
Proves a breaker will actually clear a fault fast enough to protect people and cable.
Safety switch (RCD) trip times
Measures in milliseconds how quickly each safety switch disconnects. Pressing the test button does not tell you this.
Visual inspection
Switchboard, earthing, accessible wiring, smoke alarms and anything that looks tired or unsafe.
Three steps, no surprises
Test on site
Readings go straight from the instrument into the record. Nothing is written down and retyped later.
Stored against your site
Results are saved per property, per board, per circuit, and kept for next time.
Report in your inbox
A clear PDF with pass and fail results, photos where useful, and plain-English recommendations in priority order.
Why people choose us for electrical safety testing & reports
Licensed electricians
Not just testers or installers. If something fails or needs fixing, we can sort it on the spot.
Results you can prove
Readings are captured digitally and stored, so you get a report and not just a tick on an invoice.
The best test gear
Fluke TruTest software, a thermal camera and the Metrel DeltaPAT 3309 BT come to every relevant job.
Fixed, upfront prices
A free quote before we start, with no hidden extras.
Planned around you
We book in times that suit and work in sections where needed, so your home or business keeps running.
Local since 2014
Based in Katoomba and on the road across the Mountains and Penrith every day.
What customers say about our electrical safety testing & reports
120 Google reviews
“Nathan is friendly and easy going. He was very quick to respond to an issue we were having with some smoke alarms. Would recommend him to anyone looking for electrical work.”
2025 · Google
“What can I say! Nathan as an electrician is recommended, good work attitude and fair price and goes beyond what is required. Nathan as a person is godsend. We are so glad we found him for our complete (indoor and outdoor) renovation job in Katoomba.”
Katoomba · 2024 · Google
“Nathan and team have always provided our short term rental business with prompt and terrific support. Highly recommend their services!”
2025 · Google
Recent work


Electrical safety testing & reports: FAQs
What do I get at the end?
A PDF report generated from the stored test data. It lists each circuit tested, the measured values, pass or fail against the relevant limits, and a prioritised list of anything that needs attention. It is the sort of document you can hand to an insurer, a buyer, a property manager or an auditor.
How is this different from test and tag?
Test and tag covers portable appliances and leads, the things you plug in. Safety testing and reporting covers the fixed installation itself: the switchboard, safety switches, earthing and the wiring in the building. Many workplaces need both, and we do both.
How often should an installation be tested?
It depends on the type of premises and how hard the installation works. Homes benefit from a check when they change hands or after major work. Commercial and industrial sites usually test on a regular cycle. We will recommend an interval that suits your site and risk.
Get a quote for electrical safety testing & reports
Answer a few quick questions, add a photo or two, and Nate comes back with a price. It takes about two minutes and beats waiting for a call back.
Start my quote- No obligation, upfront price
- Photos mean faster, firmer quotes
- Urgent jobs are looked at first
Often booked together
Thermal imaging inspections
A thermal camera sees the loose connection or overloaded breaker long before it trips, melts or stops production.
Find out moreTest & tag
Leads, tools and appliances tested to AS/NZS 3760 by licensed electricians, tagged on the spot and logged straight into a digital register you can hand to an inspector or insurer.
Find out moreSwitchboard upgrades
Swap the old fuse box for a modern board with a safety switch on every circuit, labelled, tested and certified.
Find out moreElectrical safety testing & reports near you
Based in Katoomba, working across the Blue Mountains, Penrith and the Hawkesbury.